non dehp drugs

  • BD I.V Sets and Accessories

    Needle Free Connectors Set Length 280 cm Priming Volume 25 ml Bore 3 mm 1 Spiked Drip Chamber s Vented/Unvented Drops per ml 20 Hydrophobic Air Inlet Filter with Cap 15 µm Drip Chamber Filter 1 SmartSite Valve Y Port.

  • DEHP

    Areas of Use of DEHP DEHP is not known to occur naturally The worldwide production of DEHP has been increasing over the past several decades Around 97 of DEHP is used as a plasticizer in polymers mainly PVC Exposure to DEHP varies widely and is dependent on Medical procedure Lipophilicity or ability of a chemical compound to dissolve in lipids of the fluid that

  • Sorption of amiodarone to polyvinyl chloride infusion bags

    The loss of amiodarone from i.v admixtures to flexible polyvinyl chloride PVC infusion bags and i.v administration sets was studied Admixtures containing amiodarone hydrochloride 600 micrograms/mL and either 5 dextrose injection or 0.9 sodium chloride injection were stored at room temperature in glass bottles both with and without contact of the drug solution with the

  • Solution Set with DUO VENT spike

    Solution Set with DUO VENT spike Manufacturer Baxter Healthcare For use with rigid non vented and flexible containers Compatible with FLO GARD 6201 and FLO GARD 6301 Series Pumps DEHP and non DEHP options available Sterile fluid path Specifications Connection Type Luer Lock.

  • SUMMARY OF THE FDA SAFETY ASSESSMENT OF DEHP

    non systemic effects The FDA notes Table 1 Selected FDA Comparisons of Tolerable Intake TI Values for DEHP to the Dose of DEHP Received During Certain Medical Procedures IV crystalline solutions IV drugs with vehicles Total Parenteral Nutrition lipid solution Enteral nutrition ECMO Exchange Transfusions Adult TI/dose ratio 120 4 5 0.3 0

  • IV Solutions

    0.9 Sodium Chloride Injection USP in both Viaflex Container and Viaflo Container non PVC non DEHP 5 Dextrose Injection USP in both Viaflex Container and Viaflo Container non PVC non DEHP Lactated Ringer’s Injection USP Plasma Lyte A Injection pH 7.4 Multiple Electrolytes Injection Type 1 USP Irrigation solutions in bags and

  • Injection Solution Sod Cl.9 100/150mL Non DEHP/Non PVC

    B Braun S8004 5264Injection Solution Sod Cl.9 100/150mL Non DEHP/Non PVC 100ml 64 EA/CA 0.9 Sodium Chloride Injection USP 100 mL Fill in 150 mL PAB Sodium Chloride Injections USP are sterile nonpyrogenic isotonic and

  • Drugs Require Non Pvc Tubing

    non DEHP tubing and non PVC infusion bags No reconstitution required Diluted drug it remains stable tack room temperature for 6 hours in Non PVC bags are compatible for the administration of drugs that held a lipophilic Safety Assessment of Di2 ethylhexylphthalate DEHP FDA Safe injection drug sequence was enhanced by multidisciplinary.

  • Doxorubicin Adriamycin Rubex Chemotherapy Drug Information

    Chemotherapy drugs that affect cells when they are at rest are called cell cycle non specific The scheduling of chemotherapy is set based on the type of cells rate at which they divide and the time at which a given drug is likely to be effective This

  • Evaluation of tacrolimus sorption to PVC

    Aug 07 2017  However in administration sets non PVC based materials such as PO generally exhibit low sorption potential compared with PVC materials Aloumanis et al 2009 Jin et al 2016 Treleano et al 2009 Trissel et al 2006 Thus drug sorption to administration set tubes should be evaluated and minimized using an alternative material or design.

  • Study Drugs that require non pvc containers Flashcards

    Start studying Drugs that require non pvc containers Learn vocabulary terms and more with flashcards games and other study tools.

  • In Line Filters

    Teniposide Use NON DEHP IV tubing with build in 0.22 micron in line filter TPN with lipids or Lipids alone Use NON DEHP IV tubing with a build in 1.2 micron filter Medications that require the use of IV filters under special circumstances Amiodarone only use filter when drug concentration other than 900mg/500ml

  • Non PVC Non DEHP IV Solutions

    VisIV Container ICU Medical offers VisIV in non PVC/non DEHP non latex IV container in 0.9 Sodium Chloride Injection USP and 5 Dextrose Injection USP available in 50 mL 100 mL and 250 mL and made for drug compatibility VisIV features large print for readability a clear container for easy inspection and sterile ports that

  • Proposition 65 Maximum Allowable Dose Level MADL for

    With regard to non oral studies in general CERHR 2000 notes No other reviewed studies were found to be useful in this regard The perinatal period potentially a time of greater susceptibility for DEHP’s reproductive effects was not tested in this study After the publication of the CERHR U.S FDA and NIOSH evaluations Cammack et al.

  • Our Products

    IV Solutions We provide a broad portfolio of IV solutions to help meet healthcare systems needs for commonly prescribed medications Learn About Our IV Solutions Products Find additional product information in our online catalog or call us at 1 888 229 0001 for customer service or to locate your sales representative.

  • FDA Manufacturers Should Label PVC Medical Devices Made

    Sep 10 2002  WASHINGTON The U.S Food and Drug Administration is recommending that manufacturers label medical devices made with di 2 ethylhexyl phthalate DEHP a chemical linked to birth defects and other illnesses that is used to soften polyvinyl chloride PVC plastic.

  • Hospira Inc

    May 14 2010  Hospira s continued transition to non DEHP will help hospitals align with the recommendations of the FDA notification by providing non DEHP medication delivery sets designed for use with neonates and additional options for use with blood and drugs and solutions that contain lipid fat all of which are product areas identified in the

  • Human Health Toxicity Risk Assessment of DEHP in

    1 Australian Government Department of Health and Ageing NICNAS Human Health Toxicity Risk Assessment of DEHP in Medical Devices NICNAS November 2007 334 336 llIawarra Rd MARRICKVILLE NSW 2204 GPO Box 58 SYDNEY NSW

  • Neonatal Exposure to DEHP di 2 ethylhexyl phthalate and

    Neonatal Exposure to DEHP and Opportunities for Prevention the US Food and Drug Administration the Center for the Evaluation of Risks to Human Reproduction at the National Toxicology Program and an expert advisory panel to Health Canada have all concluded that neonates may be exposed to levels of DEHP known to cause harm in laboratory animals

  • Hospira to Standardize Intravenous I.V Administration

    May 14 2010  Hospira began introducing non DEHP sets a number of years ago and will continue over the next year with the vast majority of DEHP sets to be discontinued by early 2011 Hospira s customers

  • An alternative to DEHP plasticized polyvinyl chloride in

    However in an effort to comply with the recommendations of the drug manufacturer many device companies are in the process of converting their devices from DEHP plasticized tubing to tubing made with non phthalate

  • Mangum Micro Fluid Delivery System Infusion

    Nov 02 2017  Non DEHP Formulation Latex Free 2.6 mL 67 170 cm MXMG Vented Non Vented Spike Mangum Micro Delivery Administration Set Pinch Clamp Back Check Valve Small Body Anti Free Flow Stopcock Small Bore Extension Male Luer Lock For use with 1cc Syringes Non DEHP Formulation Latex Free 0.5 mL 62 157 MX536020MG

  • Cladribine Professional Patient Advice

    Jul 11 2020  Drugs provides accurate and independent information on more than 24 000 prescription drugs over the counter medicines and natural products This material is provided for educational purposes only and is not intended for medical advice diagnosis or treatment Data sources include IBM Watson Micromedex updated 11 Oct 2021 Cerner Multum updated

  • Evaluation of Drug Sorption to PVC

    Mar 11 2017  Diazepam Figure 1a 1 2 tacrolimus Figure 1b 5 nitroglycerin2 and cyclosporin A3 are representative drugs with high sorption in PVC and non PVC based tubes For the evaluation of drug sorption to the tubes test conditions such as flow rate and drug concentration are based on the clinical use of the selected drugs1 6 7.

  • Incompatibilities of drug admixtures

    Incompatibilities of drug admixtures The main idea is the incompatibilities that accrue between the IV drug with drug solution container and IV set Simple study of incompatibilities of drug admixtures in Iraq that accrue heavily in pharmacy and hospitals it incorrect because the compliance of patient not a reason for admixture and we

  • Johns Hopkins Health System and Office of Injection and

    procedure See approved list of non chemotherapeutic drugs in the attached APPENDIX A Therapeutic administration non chemo of therapeutic prophylactic or diagnostic IV infusion or injection other than hydration for the administration of substances/drugs require direct supervision for patient assessment consent and safety oversight.

  • Chemotherapy and Other Hazardous Drugs Safe Use

    Drug Administration FDA and have been tested for use with chemotherapy drugs Wear a protective gown or equivalent that is lint free non permeable with a solid front long sleeves and tight fitting elastic or knit cuffs Wear long pants or long skirt and fully closed shoes 7 Wear safety glasses with side shields or goggles.

  • Non DEHP PVC and Medical Devices

    At Spectrum Plastics we noticed our customers medical device OEMs considering seriously the non DEHP alternatives about 10 years ago Largely due to potential health and exposure reasons as noted above this conversion seemed to begin with neo natal and enteral applications to reduce potential exposure We’ve since seen a migration across

  • ICU Medical

    Product Numbers List Number19715 01 shop.icumed Number EDI Number Nominal Length 7 17.78 cm Filtered No Number of Lines 1 Sterile Pack Yes Non DEHP Yes Hand Pump No Backcheck Valve No Latex Information Natural rubber latex has not been used in the manufacture of this product.

  • What is DEHP Where is it used Why is it used

    DEHP is widely used because it is low cost processes well and has provided good end use performance Why is Saint Gobain Performance Plastics developing alternative tubing products that do not contain DEHP and are non Phthalates specific to food and beverage Recently regulatory restrictions have been enacted which limit the use of DEHP.

  • TITLE STANDARD CONCENTRATION AND ADMIXTURE

    bag/bottle after ordered drug/solution as per physician’s order has been added 4 Only infusion tubing may be used and all drugs in this policy must be administered via an infusion pump The infusion pump must be programmed with the name of the drug infusing drug amount diluent titration scale i.e mcg/kg/min and weight if required .

  • Know When to Prep IV Meds With PVC Free and DEHP Free Supplies

    Know When to Prep IV Meds With PVC Free and DEHP Free Supplies April 2018 You may see more focus on appropriate use of PVC free and DEHP free IV supplies due to shortages of some of these products PVC or polyvinyl chloride is commonly used to make IV tubing and bags Viaflex etc DEHP or diethylhexyl phthalate may be used in combo

  • Di 2 ethylhexyl Phthalate Property Information

    of DEHP as a plasticizer was reported to be 40 for medical devices 30 for consumer goods and 30 for construction related applica tions Bizzari et al 2007 Non plasticizer uses of DEHP include its use in dielectric fluids for electric capacitors as an

  • Special Considerations When Administering IV Chemotherapy

    Some agents require non leaching DEHP free tubing others require an inline filter while others specifically state not to use this tubing Table 7 in Chemotherapy and Biotherapy Guidelines and Recommendations for Practice discusses special features required for administration but package inserts should be referred to for the most up to date

  • CME

    For light sensitive drugs Anti kink MicroSet 1.5x3mm lumen UV light resistant Non DEHP Latex free SR segment with dedicated set key black Anti Stretch Key round Y injection port Anti siphon anti reflux valve blue Luer Lock.

  • Helping to protect you from exposure to hazardous drugs

    DEHP free PVC free and latex free Avoids patient exposure to DEHP plasticizer Polyethylene lined sets available Prevents drug sorption Helps prevent leaching of phthalates into fluid pathway therefore avoiding patient exposure Our range of SmartSite needle free primary and secondary sets help achieve a closed system during